Тема: [HDD] [SMART] Оцінка стану жорстких дисків.
Є два майже мертвих жорстких дисків. Розмірковую над тим чи можливо якийсь з них використати для зберігання різного непотребу, ну втрата якого не є страшною. Що скажете? Чи обидва в смітник та не страждати фігнею?
P.S. Обидва диска до того як все знищив на них через shred не проходили smart short.
P.P.S. Той що на 640 ГБ до shred читався і писався більш менш, а той що на 500 ГБ більш впертий.
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.4.9-300.fc23.x86_64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line mode".
Drive command "Execute SMART Short self-test routine immediately in off-line mode" successful.
Testing has begun.
Please wait 2 minutes for test to complete.
Test will complete after Fri May 20 09:01:43 2016
Use smartctl -X to abort test.
[root@localhost HetmanNet]# smartctl -a /dev/sda
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.4.9-300.fc23.x86_64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Blue Serial ATA (AF)
Device Model: WDC WD6400BPVT-55HXZT2
Serial Number: WD-WXG1A31F7794
LU WWN Device Id: 5 0014ee 6abdbb299
Firmware Version: 01.01A01
User Capacity: 640 135 028 736 bytes [640 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Fri May 20 09:06:50 2016 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (16080) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 158) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x7035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 175 174 051 Pre-fail Always - 36164
3 Spin_Up_Time 0x0027 205 198 021 Pre-fail Always - 725
4 Start_Stop_Count 0x0032 098 098 000 Old_age Always - 2837
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
9 Power_On_Hours 0x0032 085 085 000 Old_age Always - 11387
10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 098 098 000 Old_age Always - 2827
191 G-Sense_Error_Rate 0x0032 001 001 000 Old_age Always - 5719
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 92
193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 1614214
194 Temperature_Celsius 0x0022 120 103 000 Old_age Always - 27 (Min/Max 23/45)
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 11387 -
# 2 Short offline Completed: read failure 90% 11363 207901192
# 3 Short offline Completed: read failure 90% 11363 207901192
# 4 Short offline Completed: read failure 90% 11363 207901192
# 5 Conveyance offline Completed without error 00% 9570 -
# 6 Conveyance offline Completed without error 00% 9570 -
# 7 Conveyance offline Completed: read failure 90% 9566 214779409
# 8 Extended offline Completed: read failure 90% 9522 38675504
# 9 Short offline Completed: read failure 90% 9521 38675504
#10 Conveyance offline Completed: read failure 90% 9521 38675504
#11 Extended offline Completed: read failure 90% 9521 38675508
#12 Extended offline Completed: read failure 90% 9521 38675504
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.4.9-300.fc23.x86_64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line mode".
Drive command "Execute SMART Short self-test routine immediately in off-line mode" successful.
Testing has begun.
Please wait 2 minutes for test to complete.
Test will complete after Fri May 20 09:02:03 2016
Use smartctl -X to abort test.
[root@localhost HetmanNet]# smartctl -a /dev/sdb
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.4.9-300.fc23.x86_64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Blue Serial ATA
Device Model: WDC WD5000BEVT-00A0RT0
Serial Number: WD-WX61A70W2986
LU WWN Device Id: 5 0014ee 2af88c276
Firmware Version: 01.01A01
User Capacity: 500 107 862 016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Fri May 20 09:07:13 2016 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (13200) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 154) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x7037) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 295
3 Spin_Up_Time 0x0027 151 149 021 Pre-fail Always - 3408
4 Start_Stop_Count 0x0032 095 095 000 Old_age Always - 5664
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
9 Power_On_Hours 0x0032 076 076 000 Old_age Always - 17671
10 Spin_Retry_Count 0x0032 100 100 051 Old_age Always - 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 286
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 271
193 Load_Cycle_Count 0x0032 165 165 000 Old_age Always - 107897
194 Temperature_Celsius 0x0022 121 104 000 Old_age Always - 26
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0008 100 253 051 Old_age Offline - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 17671 -
# 2 Short offline Completed: read failure 90% 17652 399671019
# 3 Extended offline Completed: read failure 90% 17630 399671019
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.